Post Options Post Options   Thanks (0) Thanks(0)   Quote marsella Quote  Post ReplyReply Direct Link To This Post Posted: 29 October 2024 at 19:30
Originally posted by Wild Wild wrote:

Yes indeed after looking at the wiring diagram.
Like Arcadia said, only if the source switch is in position generator our wallpower the relay 3K1 wil close and provide power to the hot water boiler and if installed the washer-dryer.
Sorry I am confused about 3K1, I originally thought its job is to let all high loads to operate only when shore power/generator is on, while remain open when inverter is on; Arcadia said it apliles only to boiler, Wild said it also applies to washer dryer, but whats left is only three AC switches on that panel. Do you mean that ACs can run from the inverter and the boiler cannot?
Back to Top
Arcadia View Drop Down
Admiral
Admiral
Avatar

Joined: 27 November 2017
Location: Sag Harbor, USA
Status: Offline
Points: 1112
Post Options Post Options   Thanks (0) Thanks(0)   Quote Arcadia Quote  Post ReplyReply Direct Link To This Post Posted: 29 October 2024 at 21:44
Yes, it is a bit confusing unless you look the wiring diagram which make things clear. For starters, you need to know that the aircon units and the AUX breaker are the ONLY items on the number two buss. This buss is only active when selector is on shore or generator which are needed to run the aircon loads. The boiler and washer are on the number one buss. This is done to balance the loads when all are running. However, because the boiler and washer can draw high amperage from the inverter / batteries, they need to be disconnected from buss one when not on shore / generator. This is the function of the 3K1 relay. The breaker for the boiler is on the right side of the panel along with the aircon circuits, BUT, they are not wired to buss two with the aircon circuits. There may lie the confusion.
Leon / ARCADIA
2018 Hanse 588
Sag Harbor, NY
Back to Top
marsella View Drop Down
Rear Admiral
Rear Admiral


Joined: 21 June 2022
Location: Antigua Jolly H
Status: Offline
Points: 592
Post Options Post Options   Thanks (0) Thanks(0)   Quote marsella Quote  Post ReplyReply Direct Link To This Post Posted: 29 October 2024 at 23:15
Ok, understand, thats what I also thought about 3K1 except that aircons are powered from different shore power socket that I did not have installed at first place. As it looks my problem should be with 3K1 but Mikes problem is somewhere in the second shore power line.


Back to Top
Wild View Drop Down
Vice Admiral
Vice Admiral
Avatar

Joined: 18 March 2010
Location: Turkey-Greece
Status: Offline
Points: 937
Post Options Post Options   Thanks (0) Thanks(0)   Quote Wild Quote  Post ReplyReply Direct Link To This Post Posted: 31 October 2024 at 15:45
Directly after commission our boat we changed the Victron multiplus inverter-charger 12/1600/70 by a Victron Quattro 12/3000/120 and liquidate the source switch.
The Quattro recongnized which source provides 230V and connect this one automatically to the loads with a delay of 2 min for the heavy loads like boiler, dishwasher and AC. This delay give the generator time to reach correct RPM.
On the Quattro You have the choice which one has priority:generator our wall power.
We choose generator 24Amp ,in the Med (Greece) shore power is mostly max 16Amp.
Btw I agree completely with Arcadia’s last post.
About Mikes problem check the earthleak breaker (ELCB ?) 3F1 this one is only for the AC ,AC pump and AUX 230V line.this one is after the 230 voltmeter


Edited by Wild - 31 October 2024 at 15:48
Wild and Wet
Belgium
545e#268
Back to Top
GJK View Drop Down
Sub Lieutenant
Sub Lieutenant


Joined: 11 December 2023
Location: Netherlands
Status: Offline
Points: 10
Post Options Post Options   Thanks (0) Thanks(0)   Quote GJK Quote  Post ReplyReply Direct Link To This Post Posted: 07 November 2024 at 09:57
I am looking formthe wiring diagram for
our Hanse 445 and noticed in this post that younare regering to a wiring diagram for a Hanse 445. Can someone share the diagram with me or let me know where to download this?
Thanks in advance
Gertjan
Back to Top
32mike View Drop Down
Commadore
Commadore
Avatar

Joined: 26 March 2020
Location: FLorida, US
Status: Offline
Points: 453
Post Options Post Options   Thanks (0) Thanks(0)   Quote 32mike Quote  Post ReplyReply Direct Link To This Post Posted: 07 November 2024 at 11:52
Hi guys,
Thanks for the helpful suggestions. I’ve read them all but still haven’t gotten back to the boat yet to investigate. Just wanted to let you know that I haven’t gone radio silent. As soon as I can, I will post an update.
Cheers,
Mike
Mike
S/V Dulces Sueños
458 #087
Tampa, FL