OK, for those that use it, the holding tank that came with the boat is way too small.
Has anyone added tankage and if so, where did you put it?
As an alternative to increasing holding tank size, I am considering the Lectra San unit, which is essentially a mini waste treatment system, which is approved in my sailing area as a means of going straight overboard after treatment, which then eliminates the need for a larger tank. I cannot seem to find the room to put the unit though as compartment with the tank is really tight on space. I could potentially remove the tank altogether, but would prefer not to do this. Has anyone installed such a unit?
Thanks. Jon
|
|
![]() |
|
371-#235
Captain
Joined: 14 February 2004 Location: Canada Status: Offline Points: 272 |
Post Options
Thanks(0)
Quote Reply
Posted: 11 August 2010 at 18:15 |
|
I replaced the factory holding tank with a custom made polypropylene one (still located unter the sink). It increased the capacity by about 40%. The limiting factor when you consider this is that the doorway into the head is only about 16" wide. The tank that I had fabricated was designed to the max of this dimesnion without the fittings installed yet. I installed the fittings once tha tank was in the head. This project was done in 2004 and have had no problems with it.
Also, in doing this, I negated the use of the pump that Hanse supplied for pumping out the tank. When I get the tank pumped out it is done through the deck fitting by marina pump-out services that use a vacuum/suction method.
|
|
|
Bob
371-#235 "Blondie" |
|
![]() |
|
Paule70
Sub Lieutenant
Joined: 11 July 2016 Location: Germany Status: Offline Points: 15 |
Post Options
Thanks(0)
Quote Reply
Posted: 24 July 2021 at 13:38 |
|
Hi,
I hope the thread is not too old to get an answer. My holding tank is leaking. I want to dismantle and repair or replace. However the new solution will be I have no clue how to dismantle the original tank… ? I cannot find any fittings or similar… Is it just glued with Sika at the bottom? And if so, how to destroy this? I an looking forward to any hints. BR |
|
|
Hanse 371 #129
Eckernförde, Germany |
|
![]() |
|
lucca
Lieutenant
Joined: 15 May 2006 Location: Stralsund Status: Offline Points: 47 |
Post Options
Thanks(0)
Quote Reply
Posted: 26 August 2021 at 20:20 |
|
Der Tank ist mit viel Sikka auf den Boden geklebt. Man kommt da auch sehr schlecht ran. Ich habe meinen Tank entfernt. Es hilft nur das Sikka aufzuschneiden. Ich habe mit einer Säbelsäge und Keilen das Sikka unter dem Tank aufgeschnitten. Dazu musste ich das GFK Türenelement entfernen. Man kann auch versuchen mit einer Gitarrenseite zu schneiden. Viel Erfolg.
|
|
|
371s #171, 40HP Volvo, 3-Blade FoldProp, Jefa RP150&DD1, RMC 185 4kW, Zeus2 9, V50, NAIS400, WR10, Victron MultiPlus 1600, 180W Solar, 150l Diesel, 300l H2O, Eberspächer 4kW, freezer ... ;)
|
|
![]() |
|
Sofia
Sub Lieutenant
Joined: 02 October 2017 Location: Norway Status: Offline Points: 7 |
Post Options
Thanks(0)
Quote Reply
Posted: 11 October 2021 at 11:33 |
|
Hello
I ripped out the head and the original tank two years ago, and changed to a macerating head. Pictures below. I found a tank that just fit the space underneath the bathroom countertop. Its suspended in the ceiling with cargo straps. The bottom of the tank its just above waterline, so gravity will drain it. Tank: https://webshop.nettbaat.no/products/septiktank-plast-60-liter?gclid=EAIaIQobChMI-In--Y_C8wIV2RkGAB1ecg66EAQYAyABEgKoC_D_BwE There are a lot of hose connections on the discharge line, but this was to avoid bending the hose too much. Bending the hose too tightly (stretching the material) its not good for its permeability. So far it has worked fine. ![]() ![]() ![]() ![]() |
|
![]() |
|
Sofia
Sub Lieutenant
Joined: 02 October 2017 Location: Norway Status: Offline Points: 7 |
Post Options
Thanks(0)
Quote Reply
Posted: 11 October 2021 at 11:36 |
|
And by the way. Yes, the old stainless tank is glued to a base plate. What worked well, was driving two long wooded wedges in between the tank and the floor with a hammer. The glue suddenly let go.
|
|
![]() |
|
lucca
Lieutenant
Joined: 15 May 2006 Location: Stralsund Status: Offline Points: 47 |
Post Options
Thanks(0)
Quote Reply
Posted: 25 March 2022 at 17:10 |
|
I completely removed the old tank and installed a new tank above the waterline. So I don't need a pump. Gravity is enough. ![]() ![]() ![]() |
|
|